5702 Centrifuge
Category: Centrifuge
Manufacturer: Eppendorf
Part Number: 5702

Eppendorf Centrifuge 5702 is quiet and compact, and provide exceptional value for low-speed centrifugation of tube volumes from 1.1 ml to 85 ml. With its space-saving footprint and innovative design, the 5702 series can accommodate a remarkable 30 x 15 ml round-bottom tubes or 20 x 15 ml conical tubes. Fixed-angle or Swing-bucket Rotors provide flexibility for low-speed centrifugation of sensitive cells and blood. The A-4-38 Swing-bucket Rotor can spin up to 4 x 85 ml tubes in aerosol-tight buckets at g-forces up to 3,000 x g. A variety of adapters accept all common standard, conical, and blood collection tubes. For applications requiring higher tube capacity, rectangular buckets for up to 24 x 15 ml glass tubes can be used. Two versions of the F-35-30-17 Fixed-angle Rotor are available for a capacity of up to 30 x 15 ml. A simple, 8-place Swing-bucket Rotor is also available for 15 ml conical tubes.

State-of-the-art, yet simple, these centrifuges are easy to operate. The motorized “soft-touch” lid makes loading and closing effortless. Time and Speed knobs allow you to set and adjust parameters quickly and easily. Speed can be set in rpm or RCF (g-force), eliminating the need for tedious calculations, and all settings can be changed during a run. You can also lock your settings to protect them against unintentional adjustment. Once the parameters are set, simply press the Time knob to start your preprogrammed run. When complete, an audible signal alerts you to remove your sensitive samples. The electronic brake can be deactivated in order to improve yields when spinning sensitive blood and urine samples.

Features
Speed can be set from 100 rpm to 4,400 rpm
Timer can be set up to 99 minutes or continuous
Maintenance-free drive
Dials for time and speed with clear digital display
Green-lit standby button
Display in rpm speed or g-force
Parameters can locked to avoid unintentional changes
Separate Short Spin button for quick spins
Automatic motorized lid-locking
Short braking time
Brake can be deactivated for sensitive blood and urine samples
Rotor chamber made of stainless steel
Extremely compact/small footprint
Lid opens automatically at the end of run for easy one-handed access
Natural air flow of the rotor is directed out the back of the unit for sample cooling

Contact Us for additional information.